Oil Removal Solutions for Industrial Oily Wastewater

CPI Coalescing Separator for Tank Farm Oily Water

Banner

CPI Coalescing Separator for Tank Farm Oily Water

November 25th, 2026

Tank farm wastewater is awkward by nature. Initial rainwater runoff arrives in sudden, uneven batches; tank-bottom drainage carries oil at concentrations that vary with every transfer operation. Both have to meet discharge standards consistently, in a facility that expects to run for years without the treatment unit becoming a maintenance project of its own.

The CPI high-efficiency coalescing oil separator was engineered for exactly this duty: petrochemical facilities and oil depots treating challenging oily wastewater, using mature coalescence-separation technology and industrial-grade specifications rather than laboratory assumptions. The result is stable effluent quality, simplified operation and maintenance, and compliance that holds up under inspection.

Engineered Around the Operating Envelope

Designing for this duty means starting from the operating envelope rather than from a nominal capacity figure. Flow rate, oil load, solids load, and energy consumption all move independently in tank farm service, so each specification below exists to keep one of those variables from becoming the constraint on the others.

Flow Flexibility From 60% to 120%

Rainfall-driven flow does not respect design points. A separator sized for average conditions is either overwhelmed during a storm or idling the rest of the year. The CPI unit accepts an operational flexibility range of 60% to 120%, which absorbs the flow-rate fluctuations that tank farm service produces as a matter of course.

Influent and Effluent Limits

The unit is rated to handle influent with oil content up to 1000 mg/L and suspended solids up to 300 mg/L, and to deliver effluent at or below 150 mg/L oil and 100 mg/L suspended solids. Those outlet figures matter less for the discharge permit than for what follows: they create a stable environment for downstream treatment processes, so the next stage is not being asked to absorb whatever the previous stage failed to remove.

Pressure Drop at or Below 0.2 MPa

Hydraulic resistance is a running cost. Keeping the operating pressure drop at or below 0.2 MPa keeps pumping energy low and keeps the unit economical to operate over its service life, not merely at commissioning.

Table 1. CPI coalescing separator: operating specifications

Parameter

Specification

Operational flexibility

60% – 120% of design flow

Influent oil content

≤ 1000 mg/L

Influent suspended solids

≤ 300 mg/L

Effluent oil content

≤ 150 mg/L

Effluent suspended solids

≤ 100 mg/L

Operating pressure drop

≤ 0.2 MPa

Installation

Skid-mounted, indoor temperature-controlled (heated) environment

Duty

Intermittent or continuous operation

Corrugated Plates and the Shallow-Tank Principle

The core of the design is corrugated plate coalescence, which combines gravity separation with the shallow-tank principle. Oil droplets coalesce and rise while suspended solids settle at the same time—two separations running in one passage, and at an efficiency that conventional horizontal-flow separators cannot approach.

From 1.5–2.5 Metres Down to 20–80 Millimetres

In a traditional separator, an oil droplet must rise 1.5 to 2.5 metres before it reaches a collection surface. The corrugated plate assembly cuts that distance to 20 to 80 millimetres between the plates. Because rise time scales with distance, compressing the path compresses the time: separation efficiency rises to 3–5 times that of conventional separators, and the vessel no longer needs to be tall, slow, or large.

 

Figure 1. Principle of the CPI unit: the corrugated plate pack shortens the oil rise path from 1.5–2.5 m to 20–80 mm, so oil and solids separate in one compact passage. Illustrative schematic, not to scale.

Oleophilic, Non-Stick Plates With In-Line Air Flushing

The plates are oleophilic—oil is attracted to them, which is what makes coalescence work—yet non-stick and easy to clean. Paired with an in-line flushing system using non-purified air, the pack resists clogging and delivers an extended service life. That combination matters in tank farm service, where sludge and wax-like deposits would otherwise blind a plate pack within months.

The mechanical package follows the same logic. The integrated, skid-mounted design has a compact structure that saves plot space and reduces civil engineering cost, while allowing rapid installation and quick commissioning—advantages that matter when a separator is retrofitted into a live terminal rather than built into a new plant.

Where It Belongs in the Treatment Train

The unit removes floating and dispersed oil from initial rainwater runoff at tank farms, tank-bottom drainage, produced water from oilfields, and oily wastewater from refineries—the streams where oil arrives in coherent or moderately dispersed form rather than as a tight emulsion. In each case it functions as the oil-removal pretreatment step ahead of biochemical treatment systems, protecting membrane modules and biological tanks from oil-related fouling or poisoning and extending the service life of downstream equipment.

It is designed for both intermittent and continuous operation, which suits a terminal whose wastewater arrives in batches, and it performs stably when installed indoors in a temperature-controlled, heated environment—a practical requirement in cold-climate tank farms where an unheated separator would otherwise be a seasonal liability.

Because the unit is specified as pretreatment rather than as the compliance stage itself, its value is measured by what it spares the rest of the plant: fewer filter element replacements, longer intervals between membrane cleanings, less chemical consumption, and a treatment chain that stays predictable when a drainage event arrives without warning.

Conclusion: Pretreatment Decides the Life of Everything Behind It

Oily wastewater pretreatment is usually specified late and budgeted tightly, yet it is the stage that determines how long the expensive equipment downstream will last. A separator that holds effluent oil at or below 150 mg/L and suspended solids at or below 100 mg/L across a 60–120% flow range does more than keep a permit current: it removes the chronic oil load that shortens membrane life, forces frequent cleaning, and turns compliance into a recurring crisis. Facilities specifying that first stage can review the CPI high-efficiency coalescing separator specifications and confirm the duty point against their own runoff and drainage profile.